摘要: 目的:确定剖宫产时蛛网膜下隙0.75%罗哌卡因(ropivacaine, Rop)麻醉的半数有效剂量(ED50)。方法:32名ASA Ⅰ~Ⅱ 、择期在蛛网膜下隙-硬膜外隙联合麻醉(combined spinal-epidural anesthesia,CSEA)下剖宫产产妇参加试验。第一位产妇0.75% Rop 剂量为12.8 Mg, 以相邻剂量的98.4%为剂量的变化幅度。感觉、运动神经阻滞分别以针刺法及改良Bromage 法测定。麻醉有效的指标为:蛛网膜下隙给药后10 min 内感觉平面阻滞达到T7、Bromage 达3分、切皮不痛、肌松满意。计算剖宫产时蛛网膜下隙0.75% Rop 麻醉的ED50 及其95%可信区间(CI)。结果:32名产妇中有5例麻醉效果可疑, 剔除出本研究。根据其余27名产妇序贯试验得出剖宫产时蛛网膜下隙0.75% Rop 麻醉的ED50 为11.97mg, ED50 的95%CI为11.75~12.19 mg 。结论:L3~4间隙CSEA 下剖宫产时, 蛛网膜下隙0.75%罗哌卡因麻醉的ED50 为11.97mg 。

关键词: 剖宫产, 蛛网膜下隙-硬膜外隙联合麻醉, 罗哌卡因, 半数有效剂量

Abstract: AIM:To determine the median effective dose (ED50)of spinal anesthesia 0.75% ropivacaine for cesarean section.METHODS:Thirty-two ASA Ⅰ-Ⅱ parturients undergoing elective cesarean section delivery with use of combined spinal-epidural anesthesia were enrolled in this study.The initial dose of was 12.8 Mg of 0.75%ropivacaine, and the dosing intervals were 98.4% of the preceding dosage.Doses for subsequent parturients were determined by the response of the previous parturient.Successful anesthesia was defined as a loss of sensation to an acupuncture stimulus at the T7 level, full motor blockade within 10 minutes after administration of the local anesthetic, analgesia of incision and the satisfaction of skelaxin evaluated by one operator.ED50 and its 95% confidence interval (CI)was determined with use of Dixon method.RESULTS:Five parturients were rejected out the study because of doubtful anesthsia.According to the rest twenty-seven parturients'data, the ED50 of intrathecal 0.75% ropivacaine was 11.97mg (95% confidence interval [CI], 11.75-12.19 mg).CONCLUSION:The ED50 of spinal 0.75% ropivacaine for cesarean delivery under the conditions of this study were 11.97mg.

Key words: cesarean section, combined spinalepidural anesthesia, ropivacaine, median effective dose