Welcome to Chinese Journal of Clinical Pharmacology and Therapeutics,Today is Share:

Chinese Journal of Clinical Pharmacology and Therapeutics ›› 2006, Vol. 11 ›› Issue (4): 444-447.

Previous Articles     Next Articles

Measurement of recombinant human glucagon-like peptide-1 (7-36) concentration by ELISA kit methods

ZHENG Zhuan-jie, FANG Yi, WANG Rui   

  1. Department of Clinical Pharmacology, PLA General Hospital, Beijing 100853, China
  • Received:2006-02-12 Revised:2006-03-21 Online:2006-04-26 Published:2020-12-08

Abstract: AIM: To qualitatively detect the concentration of recombinant human glucagon-like peptide-1 (7-36) [rhGLP-1(7-36)] in human blood.METHODS: RhGLP-1 (7-36) concentrations of standard and blood samples were detected by ELISA kits.RESULTS: The parameters of specificity, sensitivity, detection limits, reproducibiltiy and recovery can meet the requirements for pharmacokinetic studies.CONCLUSION: The concentrationmeasuring method of rhGLP-1(7-36) in blood samples using ELISA kit produced by LINCO company can meet the detection methods of biological production, which can be used as a measuring method of rhGLP-1(7-36) concentration and for its pharmacokinetic studies.

Key words: glucagon-like peptide-1, ELISA, blood concentration

CLC Number: